Troubleshooting

Is it supposed to
be doing that?


Backflow assemblies have a small vocabulary. A leak from one place means something different from a leak from another, and one of them is the device working correctly. Here is how to read what yours is telling you — and who actually handles it.

Who handles what

Getting this sorted quickly usually means calling the right trade first. Here is the honest split.

Hammerhead does this

  • Testing assemblies with calibrated gauges
  • Filing the report with your water provider
  • Tracking due dates and keeping records
  • Identifying what you have and what it needs

We do not do this

  • Repairs, rebuilds and replacements
  • Stopping an active leak
  • Emergency or same-day call-outs
  • Anything that needs parts on a truck

So if water is running and needs to stop, whoever does repairs for the property will get you sorted faster than we can — that is a different job from testing, and we would rather point you straight at it. Every entry below names who handles it. Most of them are not us, and that is the point of the page.

You will see Virginia Master Plumber in our credentials, and it is real — it is part of why the testing is done properly. Hammerhead Flow Co. still takes testing and compliance work only.

If water is actively running right now

  1. Work out where it is coming from. Underneath the body is a relief valve doing its job. From the cap on top of an upright device is a different fault. From a crack or split is freeze damage.
  2. Stop the water if it needs stopping. If you know where your shutoff valve is and can reach it safely, closing it stops the flow.
  3. Get a repair service out. A running assembly needs parts, and that is a different job from testing it.
  4. Deal with the compliance side afterwards. Once it is repaired it will need testing and the report filed. That part is ours, and it is not urgent on the same clock.

Everything below describes what a symptom generally means, how soon it needs attention, and who handles it. None of it is a repair instruction, and none of it is a diagnosis of your particular assembly — that takes gauges on the device.

By symptom

What it is telling you

Find the one that matches what you are looking at. The blue row tells you who to ring.

Water running out from underneath the assembly

Urgent if it is running
What you are seeing
A steady drip, a trickle, or an open stream coming from a port on the underside of a horizontal assembly, often into a funnel or onto the ground. Only an RPZ has this.
What it usually means
The relief valve has opened. That is the assembly doing exactly what it was built to do — it dumps water rather than let it move back toward the supply. It opens because a check valve inside is not holding, because supply pressure dropped, or because debris got in after work on the main.
How urgent
A trickle that stops on its own may be a pressure event. A stream that does not stop means the assembly needs work now — it will keep discharging, and on an indoor assembly that is a flooding problem as well as a compliance one.
Who to call
A repair service.Stopping it means opening the assembly and replacing parts. Hammerhead is a testing and compliance company and does not take repair work, so calling us will not stop the water.
What to do first
If it is flooding and you know where your shutoff is and can reach it safely, closing it stops the water. Note whether it is dripping or running and whether anything changed recently — a main break, hydrant use, work on the property. That detail saves whoever you call a lot of time.

Water spitting from the cap on top during start-up

Usually normal
What you are seeing
A vertical assembly in a mulch bed spits or sprays water out from under its cap when the irrigation turns on.
What it usually means
On a standard pressure vacuum breaker, a brief discharge at start-up is normal and expected. Air is being pushed out as the line fills. It is the reason the spill-resistant version of the device exists.
How urgent
A few seconds at start-up is not a problem. Water that keeps coming out after the zone is running, or that sprays continuously, is a different story — the air inlet is not sealing.
Who to call
Nobody, if it lasts seconds.If it is continuous, it needs parts — whoever does plumbing or irrigation repairs for the property.
What to do first
Time it. Seconds is normal, continuous is not. Either way it will show up on the next annual test, so it is worth noting the date you first saw it.

Water coming from the assembly in freezing weather

Urgent
What you are seeing
Water from a cracked body, a split bonnet, a separated cap, or visible ice on or around the assembly.
What it usually means
Freeze damage. Water expands as it freezes and brass does not. This is the single most common way assemblies die on this coast, and it usually happens to devices that were never drained for winter.
How urgent
Urgent. A split assembly can run continuously, and the damage does not repair itself when it thaws.
Who to call
A repair service.A cracked assembly has to be rebuilt or replaced. That is repair work, and Hammerhead does not take it.
What to do first
If you know where your shutoff is and can reach it safely, closing it stops the water. A photograph of the damage helps whoever you call arrive with the right parts.

The assembly is sitting in standing water

Needs attention
What you are seeing
An assembly partly or fully submerged — in a flooded valve box, a pit that has taken on water, or ground that stays saturated.
What it usually means
For an RPZ this is a real problem. Its relief port has to discharge to open air; submerged, that port becomes a path into the assembly rather than out of it. That is why an RPZ is never permitted in a below-grade vault.
How urgent
Not an emergency in the flooding sense, but the protection is compromised while it stays that way, and it will not pass a test.
Who to call
A repair or drainage service.The fix is usually the installation rather than the assembly, so it is site work rather than testing.
What to do first
Note how it got there — drainage, a failed sump, a pit that was never the right home for that device. Worth raising before the next test rather than after it fails one.

No water downstream — the irrigation will not run

Needs attention
What you are seeing
A zone or a whole system that gets no water, with a backflow assembly upstream of it.
What it usually means
Most often a shutoff valve on the assembly is closed — sometimes left that way after winterisation, sometimes closed deliberately and forgotten. It can also mean a check valve has failed closed, or the assembly froze and seized.
How urgent
Not an emergency, but the season is short.
Who to call
Whoever services your irrigation, or a repair service.Diagnosing and restoring flow is service work. Hammerhead does not take it.
What to do first
Nothing that involves opening the assembly. If a valve was simply left closed after winterisation, whoever winterised it will know which one.

The tag is missing, illegible, or years out of date

Compliance issue
What you are seeing
No tag on the assembly, a tag you cannot read, or a tag whose last test date is more than a year old.
What it usually means
Nothing mechanical. But if the last documented test is over a year old, the assembly is very likely out of compliance with whatever your water provider requires — and the provider may already have a notice on file against the property.
How urgent
Not a water emergency. It becomes urgent when a notice arrives or a property changes hands.
Who to call
This one is us.Testing and getting the report filed is exactly what Hammerhead does.
What to do first
Find out who your water provider is and what they have on record. The water provider reference page on this site is a starting point.

Someone added a valve or a hose after the device

Protection defeated
What you are seeing
A shutoff valve, a quick-connect, a hose, or new piping installed downstream of an atmospheric vacuum breaker or a hose-bibb breaker.
What it usually means
That device only works when nothing holds pressure against it. Put a valve after it and it stops protecting anything, whatever it looks like from outside. This happens by accident constantly — someone adds a convenience and has no idea what it defeated.
How urgent
No leak, no symptom, no warning. That is exactly what makes it worth raising.
Who to call
A repair service, to correct it.We can flag it at a test, but changing what is installed is repair work.
What to do first
Note it. It usually means the wrong type of device is now in that position for how the line is being used, which is a design question before it is a parts question.

Banging or knocking in the pipes after a test

Usually settles
What you are seeing
Water hammer, knocking, or spitting fixtures in the hours after an assembly was tested or serviced.
What it usually means
Air introduced into the line during the test working its way out. Testing an assembly means opening and closing it, and some air gets in.
How urgent
Usually settles on its own as the system is used.
Who to call
Nobody, usually.If it is still happening after a couple of days, that is a plumbing question rather than a testing one.
What to do first
Run the fixtures normally and give it a day or two. Tell us if it followed one of our visits — we want to know either way.

Two things to never do

Never plug, cap, or block a relief valve port. It is tempting when an RPZ is discharging onto a walkway, and it is the most dangerous thing anyone does to one of these. That port is the entire safety function. Blocked, the assembly looks fine, stops making a mess, and quietly stops protecting the water supply — which is the exact failure it was installed to prevent.

Never add a valve, hose, or fitting downstream of a vacuum breaker. Those devices only work with no pressure held against them. Anything added after one defeats it, even though nothing about it looks different afterward.

Straight answer

Why we cannot tell you what is wrong over the phone

A backflow assembly fails on the inside, against rubber seats, under a few pounds of differential pressure. Nothing about that is visible, and a tired check valve will often seal perfectly at rest and let go under exactly the conditions it was installed to handle. Determining whether one is holding takes a calibrated differential-pressure gauge on the test cocks.

So what this page does is narrow it down: whether what you are seeing is normal, whether it can wait, and which trade to ring. Anyone who tells you what is wrong with your assembly without putting gauges on it is guessing.

Where we fit

After the repair, not during it

A repaired or replaced assembly has to be tested and the result filed before the property is back in compliance — and in most jurisdictions a replacement starts a fresh annual cycle from that date. That is the part we handle, and it is where a repair service will usually hand you back.

It is also why we do not chase the emergency. A leak is a repair, and repairs are not ours at any size — no volume of work changes that.

Scheduling is a separate question, and the answer there depends on how much is in one place. Work is grouped into planned service trips, so a portfolio with enough assemblies to fill a day can justify its own trip and be turned around quickly when a deadline calls for it. A single assembly rides along with the next trip already heading that way. Either way you get a date when you book rather than a maybe — how scheduling works covers it properly.

So: get it repaired by whoever can get there. Then tell us it is done, and the testing and filing get scheduled from there.

Repaired, replaced, or just overdue?

Once the water has stopped and the work is done, the test and the filing are what put the property back in compliance. That part is ours, and it is worth booking before the next deadline rather than after it.